| Drinking Water Matrix |
| Analyte |
Method |
Sample Quantity1 |
Container Type |
Preservation |
Hold Time |
| Wet Chemistry |
|
|
|
|
|
| Aggressive Index |
SM2320B |
1 L |
plastic or glass |
none |
immediately (pH) |
| Acidity |
SM2310B |
200 ml |
plastic or glass |
cool 4oC |
14 days |
| Alkalinity -Total |
SM 2320B |
200 ml |
plastic or glass |
cool 4oC |
14 days |
| Bromide |
EPA 300.0 |
100 ml |
plastic or glass |
none |
28 days |
| Carbon Dioxide |
SM4500-CO2-C |
500 ml |
plastic or glass |
none |
immediately |
| Chloride |
SM 4500-Cl- E / 300.0 |
100 ml |
plastic or glass |
none |
28 days |
| Color |
SM 2120B |
100 ml |
plastic or glass |
cool 4oC |
48 hours |
| Conductance, Specific |
SM 2510B |
200 ml |
plastic or glass |
cool 4oC |
28 days |
| Corrosivity (pH only) |
EPA 150.1 & 4500(H+)B |
100 ml |
plastic or glass |
none |
immediately |
| Cyanide-Total |
EPA 335.4 |
250 ml |
plastic or glass |
cool 4oC, NaOH
pH>12 |
14 days |
| Fluoride |
SM 4500-F- C / 300.0 |
100 ml |
plastic or glass |
cool 4oC |
28 days |
| Nitrogen-Nitrate |
EPA 300.0 |
100 ml |
plastic or glass |
cool 4oC |
48 hours |
| Nitrogen-Nitrite |
EPA 300.0 |
100 ml |
plastic or glass |
cool 4oC |
48 hours |
| Nitrogen-Nitrate+Nitrite |
EPA 335.2 / 300.0 |
100 ml |
plastic or glass |
cool 4oC, H2SO4
pH<2 |
28 days |
| Odor |
EPA 2150B |
100 ml |
plastic or glass |
cool 4oC |
24 hours |
| pH |
EPA 150.1 |
100 ml |
plastic or glass |
none |
immediately |
| Phosphate-Ortho |
EPA 365.1 |
200 ml |
plastic or glass |
filter immediately, cool 4oC |
48 hours |
| Solids-Dissolved |
SM 2540C |
100 ml |
plastic or glass |
cool 4oC |
7 days |
| Sulfate |
SM 4500-SO42-
F / 300.0 |
200 ml |
plastic or glass |
cool 4oC |
28 days |
| Temperature |
SM 2550 |
NA |
NA |
none |
none (on site) |
| Turbidity |
EPA 180.1 |
100 ml |
plastic or glass |
cool 4oC |
48 hours |
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| 1 - This does not include the volume
necessary to perform MS/MSD analyses. Include additional sample (normally
3 times the quoted volume or mass) for each sample requiring an MS/MSD.
This extra sample volume should always be included for at least one sample
in sample sets of 5 or greater. Contact the laboratory for more
information. |
|